Site Overlay

Rebar Corrosion Canin +

Canin + rebar corrosion instrument

We are delighted to have added the Canin + rebar corrosion Half-Cell potential meter to our hire fleet. The Canin + was manufactured by Proceq for measuring the corrosion potential of steel within concrete structures.

Our Canin + rebar corrosion instrument utilises the same copper/copper sulphate single rod electrode and single corrosion wheel as the Profometer corrosion.  Like the new Profometer unit the wheel electrode allows for fast coverage of large areas. It will automatically record results for complete analysis using the Canin Provista software.

Features

  • Immediate presentation of test area and reading directly on the instrument’s display
  • Total memory for 235’000 readings which can be stored
  • For further analysis, the Proceq Canin ProVista software allows downloading, presenting and editing data measured by the instrument for corrosion analysis
  • Rapid corrosion analysis of large areas using the 1 wheel elcetrode
  • Accurate location of areas of active reinforcement corrosion

Product Variations

Variations of the Proceq Canin+ are available depending on the accessories selected:

  • Best for corrosion analysis in areas below 20 m2:
    Proceq Canin+ rod electrode for potential measurements
  • Best for corrosion analysis in areas between 20 m2 and 100 m2:
    Proceq Canin+ with 1-wheel electrode for potential measurements

Applications

  • Rapid corrosion analysis of large areas using the 1 wheel electrode
  • Accurate location of areas of active reinforcement corrosion

Technical Data

Corrosion Analysis with the Potential Measurement
Measurement range -999 mV to +340 mV
Resolution 1 mV
Memory non-volatile memory for up to 235’000 measurements stored in up to 71 object files
Software Proceq Canin ProVista Software for downloading data and evaluation on PC
Battery operation six LR 6 (AA) batteries, 1.5 V for up to 60 h (or 30 h with activated backlight)
Memory non-volatile memory for up to 5’800 measurements stored in up to 24 object files
Data transfer by Windows Hyperterminal
Battery operation six LR 6 (AA) batteries, 1.5 V for up to 40 h (or 20 h with activated backlight)
General
Impedance 10 MΩ
Operating temperature 0° to 60° C
Storage temperature -10° to 60° C
Display 128 x 128 pixel graphic LCD with back light
Data output RS 232 interface, USB with adapter
Case dimensions 580 x 480 x 210 mm (22.8 x 18.9 x 8.3 in.)
Weight net. 10.6 kg (23.5 lbs); shipping 14 kg (31.1 lbs)

 

 

For more comprehensive concrete corrosion analysis we recommend pairing the Canin + with a Proceq Resipod, Schmidt hammer and carbonation sampling kit. All of which are available from us.

We also offer the Elcometer 331 cover meter combined Half-Cell kits and the latest Profometer Corrosion.

The operating instructions for the Canin + can be downloaded from here.

CANIN rebar corrosion -Provista software -Manual

Please contact us for further information or to hire today!

Canin + Rebar Corrosion 1

 

Call Now